Chamber model: CH22000 C VT LN2
|
- Tests: temperature, humidity, vacuum
- External dimensions (chamber only) 5800x3000x(3540÷3940)mm (WxDxH)
- Internal useful dimensions: 5500x1850x2000mm (WxDxH)
- Temperature range: -60°C / +90°C
- Temperature variation rate:
- 10°C/min from -60°C up to +90°C
- 10°C/min from +90°C down to -60°C
- Relative humidity range: from 10% to 95% (dew point range +4°C/+59°C)
- Special features:
- floor interfacing with external shakers
- hydraulic lifting system
- Standard requested: BS 2011-IEC 68-2-32/50, MIL-STD-810G
|
Chamber model: SOLAR SIMULATION PLANT
|
- Test: solar simulation
- External dimensions 8600x16500x100000mm (WxDxH)
- Internal useful dimensions: 8000x16000x7600mm (WxDxH)
- Temperature range: +32°C / +49°C
- Temperature variation rate:
- 0.05°C/min from +32°C up to +49°C
- 0.05°C/min from +49°C down to +32°C
- Special features:
- wide solar radiation area 6000x13000 mm (WxD)
- hydraulic lifting system for lamps structure
- Standard requested: MIL-STD-810E method 505.3
|
Chamber model: SD 1000 MIL
|
- Tests: sand and dust
- External dimensions (chamber only) 6500x3300x2300 mm (WxDxH)
- Internal useful dimensions: 1000x1000x1000mm (WxDxH)
- Temperature range: ambient / +66°C
- Relative humidity range: below 22%
(dew point range -5°C/+84°C
- Air speed: up to 29m/s
- Standard requested: MIL-STD-810F Method 510.4
|
Chamber model: AnyVib
|
- External dimensions (typically): 2000x3476x2280mm (WxDxH)
- Internal dimensions (typically): 1000x1130x1080mm (WxDxH)
- Temperature range: -75°C / +180°C
- Relative humidity range: from 10% to 95%
- Standard requested: STD-810F Method 520.2
|
Chamber model: CHADF-Explosives
|
- Tests: combined temperature-humidity
- Temperature range: -55°C / +85°C
- Relative humidity range: from 10% to 95%
- Standard requested: MIL-STD-810F, ITOP4-2-602
|
Chamber model: UC50-60130 CST
|
- Tests: The chamber consists of two testing rooms which can work independently or together to perform thermal shock tests and/or test profiles
- Useful dimensions:
Chamber (1): 3000x4000x2000mm (WxDxH)
Chamber (2): 3000x4000x2000mm (WxDxH)
- Temperature range: -60°C / +130°C
- Temperature rate (average value, with 300kg of compact aluminium load, in the testing range -54°C/+120°C):
- Room (1) : 3°C/min heating, 2°C/min cooling
- Room (1) : 3°C/min heating, 2°C/min cooling
- Large Room (1 +2) : 3°C/min heating, 2°C/min cooling
- Thermal shock resetting time:
5 minutes in the range -40°C/+60°C, with 300kg of compact aluminium load
- Humidity range:
from 10% to 95% R.H. in the temperature range +20°C/+80°C
- Standard requested: MIL-STD810G
|
Chamber model: UC507-5575
|
- Tests on heavy vehicles
- Internal useful capacity: 507m³ approx.
- Internal useful dimensions: 6500x13000x6000mm (WxDxH)
- Door useful dimensions: 5600x5600mm H
- Floor capacity: 65 tons (in full area)
- Temperature range: -55°C / +75°C (adjustable)
- Temperature accuracy (at steady conditions): ±1...±2°C
- Average temperature rate (without internal load):
- heating up from -55°C to +75°C → 0.5°C/min
- cooling down from +75°C to -55°C → 0.5°C/min
- Climatic range (without any heat load): +10°C/+75°C
- Humidity range: from 10% to 95% R.H. (adjustable)
- Air velocity (around the specimen): 0.25 m/sec
- Standard requested:
MIL-STD-810F Meth. 501.4 Proc. 1 & II, Meth. 502.4 Proc. I, II & III, MIL-STD-810F Meth. 507.4
|
|
|