QUALITY THROUGH COMMITMENT
Profile
ACS Chambers
MRTP Systems
General Purpose Ovens
Data Loggers
Controllers
Service / Maintenance
Refurbish
Calibration
Chamber Hire
Vibration Systems
Used Chambers
Eco Friendly Chambers
F-Gas Regulations
|
|
Feature of the Month: June 2011
Examples of ACS products for Space Applications
Back to feature
Chamber model: HVT 35MC - 5080
|
- Tests: high vacuum temperature
External dimensions (chamber only) 4000x10300x4000 mm (WXDXH)
- Internal useful dimensions: 3500x5000mm (θxL)
- Internal useful volume: 35m³
- Temperature range: -50°C / +80°C
Temperature variation rate:
-2°C/min from -50°C up to +80°C with 2000kg internal load
-2°C/min from +60°C down to -50°C with 2000kg internal load
- Vacuum limit: 1x10-6 mbar
- Special features: combined thermo-vacuum tests and optical measurements on satellite
components
|
Chamber model: HVT 240MC-190130 GN2/LN2
|
- Tests: high vacuum temperature
External dimensions (chamber only) 7200x16000x9000 mm (WXDXH)
- Internal useful dimensions: 5500x1000mm (θxL)
- Internal useful volume: 240m³
- Temperature range: -190°C / +130°C
Temperature variation rate:
-1°C/min from -100°C up to +100°C
-1°C/min from +100°C down to -100°C
- Vacuum limit: 1x10-6 mbar
- Special features:
-Door with tilting system for spacecraft loading
-Special trolley for spacecraft loading on rails
-Internal monorail crane
-Spacecraft horizontality control system
|
Chamber model: TC67-185210 LN2
|
- Tests: high vacuum temperature
External dimensions (chamber only) 4000x10300x4000 mm (WXDXH)
- Internal useful dimensions: 3500x5500x3500mm (WXDXH)
- Internal useful volume: 67m³
- Temperature range: -185°C / +210°C
Temperature variation rate:
-20°C/min from -145°C up to +170°C
-20°C/min from +170°C down to -145°C
|
Chamber model: HVT 52MC-190150 LN2
|
- Tests: high vacuum temperature
External dimensions (chamber only) 4200x10000x4400 mm (WXDXH)
- Internal useful dimensions: 3900x4400mm (θxL)
- Internal useful volume: 52m³
- Temperature range: -190°C / +150°C
Temperature variation rate:
-1°C/min from -100°C up to +100°C
-1°C/min from +100°C down to -100°C
- Vacuum limit: 1x10-6 mbar
- Special feature: internal DUT frame with horizontality control system
|
Chamber model: HVT1100-150150 GN2
|
- Tests: high vacuum temperature
External dimensions (chamber only) 2000x3500x2500 mm (WXDXH)
- Internal useful dimensions: 1000x1400mm (θxL)
- Internal useful volume: 1100 l
- Temperature range: -150°C / +150°C
Temperature variation rate with load under 8x10-4 Pa:
>=-1.5°C/min in the range of -120°C / +120°C with load
>=-1.0°C/min in the range of -150°C / -120°C and +150°C / +120°C with load
- Vacuum limit: 5x10-7 mbar
|
Acotec Clean Room
|
Acotec, a subsidiary of the Angelantoni Group is specialized in the design,
implementation and validation of controlled contamination environments (clean rooms)
for aerospace applications.
- Design and production in compliance with ISO 14644
- Control contamination classes from ISO class 9 TO ISO Class 5 with the possibility to comply with ISO Class 3 for micro-environments
- Supply of customized turnkey clean rooms of any size
- Control of temperature, humidity and ambient pressure parameters with high levels of tolerance levels
- Systems for continuous monitoring of particle contamination and critical parameters
|
|
|
PREVIOUS MONTHLY FEATURES:
2012
2011
2010
2009
2008
2007